Skip to main content
PLCXpert Wiki

Schneider Modicon Quantum Digital Output Modules Compared

11 models · Schneider Electric

AI-generated · verify with manufacturer

Quantum discrete output modules drive actuators, relays and indicators from the controller. This page compares output count, voltage, logic type, response time, power dissipation and isolation across the available variants.

Specification comparison table

Schneider Modicon Quantum Digital Output Modules Compared — specifications compared across 11 models. Scroll horizontally to see all columns.
ModelRange / PlatformProduct / Component TypeNumber of OutputsOutput VoltageLogic / Output TypeResponse TimePower DissipationIsolationBus Current
140DDO15310Not availableNot availableNot availableNot availableNot available≤ 250 µs (resistive load)Not availableGroup-to-group: 500 Vrms for 1 min350 mA @ 5 V DC
140DDO15310CModicon Quantum automation platformTTL discrete output module325 V DCTTL Positive (sink)Not available4 W Maximum supply current 0.4 A500 Vrms for 1 minute2800 mA 5 V DC
140DDO35300Modicon Quantum automation platformDc discrete output module32limitsNot available<= 1 ms at state 0 to state 1 <= 1 ms at state 1 to state 01.75 W + (0.4 V x total module load current)500 Vrms DC for 1 minuterequirement
140DDO35300CModicon Quantum automation platformDc discrete output module32limitsNot available<= 1 ms at state 0 to state 1 <= 1 ms at state 1 to state 01.75 W + (0.4 V x total module load current)500 Vrms DC for 1 minuterequirement
140DDO35301Modicon Quantum automation platformDc discrete output module32limitsNot available<= 0.1 ms at state 1 to state 0 <= 1 ms at state 0 to state 15 W500 Vrms DC for 1 minuterequirement
140DDO35301CModicon Quantum automation platformDc discrete output module32limitsPositive logic (source)Not available5 W500 Vrms DC for 1 minuteRequirement 330 mA
140DDO35310Modicon Quantum automation platformDc discrete output module32limitsNot available<= 1 ms at state 0 to state 1 <= 1 ms at state 1 to state 02.0 W + (0.4 V x total load current)500 Vrms DC for 1 minuterequirement
140DDO35310CModicon Quantum automation platformDc discrete output module32limitsNegative logic (sink)<= 1 ms at state 0 to state 1 <= 1 ms at state 1 to state 02.0 W + (0.4 V x total load current)500 Vrms DC for 1 minuteRequirement 330 mA
140DDO36400CModicon Quantum automation platformDc discrete output module96limitsNot availableNot available7 Wbetween channels and busRequirement 250 mA
140DDO84300Modicon Quantum automation platformDc discrete output module1610...60 V DCNot available<= 1 ms at state 0 to state 1 <= 1 ms at state 1 to state 01 W + (1 V x total module load current)700 Vrms DC for 1 minute160 mA
140DDO84300CModicon Quantum automation platformDc discrete output module1610...60 V DCNot availableNot available1 W + (1 V x total module load current)700 Vrms DC for 1 minute160 mA

Values reproduced from manufacturer datasheets. "Not available" means the field is absent from the published source document. Always confirm critical parameters with the original documentation before specification.