Bently Nevada 3300 NSv Proximity Probes — 330908 Series Compared (Set 2): side-by-side comparison of 30 sibling models from the same product line. Every value is extracted from the manufacturer documentation indexed in this wiki; a field shown as "Not available" is absent from the published source. Use the product links for full specifications, maintenance notes and sourcing guidance.

Specification comparison table

Bently Nevada 3300 NSv Proximity Probes — 330908 Series Compared (Set 2) — specifications compared across 30 models. Scroll horizontally to see all columns.
ModelProduct / Component TypeAgency Approval OptionOverall Case Length OptionTemperatureTotal Length OptionUnthreaded Length OptionConnector & Cable OptionProbe Case Material
330908-00-30-05-02-003300 NSv Proximity Probes00 Not required30=3 in-52°C to +177°C (-62°F to05 0.5 meter (20 in)00 = 0.0 in02 = Miniature coaxial ClickLoc connector, standard cableAISI304 stainless steel (SST).
330908-00-30-10-01-05Not available-05= Multiple Approvals-30=3.0 inSchedule10 = 1.0 meter (39 in)-00= 00 inNot availableNot available
330908-00-30-10-01-CNNot available-CN=Country Specific-30=3.0 inSchedule10 = 1.0 meter (39 in)-00= 00 inNot availableNot available
330908-00-31-05-02-003300 NSv Proximity Probes00 Not required31=3.1 in-52°C to +177°C (-62°F to05 0.5 meter (20 in)00 = 0.0 in02 = Miniature coaxial ClickLoc connector, standard cableAISI304 stainless steel (SST).
330908-00-31-05-02-053300 NSv Proximity Probes05 Multiple Approvals31=3.1 in-52°C to +177°C (-62°F to05 =0.5 meter (20 in)00 = 0.0 in02 = Miniature coaxial ClickLoc connector, standard cableAISI304 stainless steel (SST).
330908-00-31-10-02-003300 NSv Proximity Probes00 Not required31=3.1 in-52°C to +177°C (-62°F to10 1.0 meter (39 in)00= 0 in02 = Miniature coaxial ClickLoc connector, standard cableAISI304 stainless steel (SST).
330908-00-31-10-02-053300 NSv Proximity Probes05 Multiple Approvals31=3.1 in-52°C to +177°C (-62°F to10 1.0 meter (39 in)00= 0 in02 = Miniature coaxial ClickLoc connector, standard cableAISI304 stainless steel (SST).
330908-00-31-70-02-003300 NSv Proximity Probes00= Not required31=3.1in-52°C to +177°C (-62°F to70 7.0 meters (23.0 feet)00= 0in02= Miniature coaxial ClickLoc connector,standard cableAISI304 stainless steel (SST).
330908-00-31-70-02-053300 NSv Proximity Probes05=Multiple Approvals31=3.1in-52°C to +177°C (-62°F to70 7.0 meters (23.0 feet)00= 0in02= Miniature coaxial ClickLoc connector,standard cableAISI304 stainless steel (SST).
330908-00-36-05-02-053300 NSv Proximity Probes05 Multiple Approvals36=3.6 in-52°C to +177°C (-62°F to05 0.5 meter (20 in)00 = 0.0 in02 = Miniature coaxial ClickLoc connector, standard cableAISI304 stainless steel (SST).
330908-00-36-10-02-003300 NSv Proximity Probes00 Not required36=3.6in-52°C to +177°C (-62°F to10 1.0 meter (39 in)00= 0 in02 = Miniature coaxial ClickLoc connector, standard cableAISI304 stainless steel (SST).
330908-00-36-10-02-053300 NSv Proximity Probes05 Multiple Approvals36=3.6. in-52°C to +177°C (-62°F to10 1.0 meter (39 in)00= 0 in02 = Miniature coaxial ClickLoc connector, standard cableAISI304 stainless steel (SST).
330908-00-36-70-02-003300 NSv Proximity Probes00 Not required36=3.6in-52°C to +177°C (-62°F to70 7.0 meters (23.0 feet)00= 0in02= Miniature coaxial ClickLoc connector,standard cableAISI304 stainless steel (SST).
330908-00-36-70-02-053300 NSv Proximity Probes05Multiple Approvals36=3.6in-52°C to +177°C (-62°F to70 7.0 meters (23.0 feet)00= 0in02= Miniature coaxial ClickLoc connector,standard cableAISI304 stainless steel (SST).
330908-00-46-05-02-003300 NSv Proximity Probes00 Not required46=4.6 in-52°C to +177°C (-62°F to05 0.5 meter (20 in)00 = 0.0 in02 = Miniature coaxial ClickLoc connector, standard cableAISI304 stainless steel (SST).
330908-00-46-05-02-05Not available-05=Multiple Approvals-46=4.6 inSchedule05= 0.5 meter (20 in)-00= 0 inNot availableNot available
330908-00-46-10-02-003300 NSv Proximity Probes00 Not required46=4.6in-52°C to +177°C (-62°F to10 1.0 meter (39 in)00= 0 in02 = Miniature coaxial ClickLoc connector, standard cableAISI304 stainless steel (SST).
330908-00-46-10-02-053300 NSv Proximity Probes05Multiple Approvals46=4.6in-52°C to +177°C (-62°F to10 1.0 meter (39 in)00= 0 in02 = Miniature coaxial ClickLoc connector, standard cableAISI304 stainless steel (SST).
330908-00-46-70-02-003300 NSv Proximity Probes00 Not required46=4.6in-52°C to +177°C (-62°F to70 7.0 meters (23.0 feet)00= 0in02= Miniature coaxial ClickLoc connector,standard cableAISI304 stainless steel (SST).
330908-00-46-70-02-053300 NSv Proximity Probes05=Multiple Approvals46=4.6in-52°C to +177°C (-62°F to70 7.0 meters (23.0 feet)00= 0in02= Miniature coaxial ClickLoc connector,standard cableAISI304 stainless steel (SST).
330908-00-53-10-02-053300 NSv Proximity Probes05Multiple Approvals53=5.3in-52°C to +177°C (-62°F to10 1.0 meter (39 in)00= 0 in02 = Miniature coaxial ClickLoc connector, standard cableAISI304 stainless steel (SST).
330908-00-55-05-02-00Not available-00 = Not required-55=5.5 inSchedule05= 0.5 meter (20 in)-00= 0 inNot availableNot available
330908-10-55-05-02-00Not available-00 = Not required-55=5.5 inSchedule05= 0.5 meter (20 in)-10= 1.0 inNot availableNot available
330908-12-08-05-02-003300 NSv Proximity Probes00 Not required08=0.8 in-52°C to +177°C (-62°F to05 0.5 meter (20 in)12= 1.2 in02 = Miniature coaxial ClickLoc connector, standard cableAISI304 stainless steel (SST).
330908-12-08-05-02-053300 NSv Proximity Probes05 Multiple Approvals08=0.8 in-52°C to +177°C (-62°F to05 0.5 meter (20 in)12= 1.2 in02 = Miniature coaxial ClickLoc connector, standard cableAISI304 stainless steel (SST).
330908-12-08-10-02-003300 NSv Proximity Probes00 Not required08=0.8in-52°C to +177°C (-62°F to10 1.0 meter (39 in)12= 1.2in02 = Miniature coaxial ClickLoc connector, standard cableAISI304 stainless steel (SST).
330908-12-08-10-02-053300 NSv Proximity Probes05Multiple Approvals08=0.8in-52°C to +177°C (-62°F to10 1.0 meter (39 in)12= 1.2in02= Miniature coaxial ClickLoc connector,standard cableAISI304 stainless steel (SST).
330908-12-08-70-02-003300 NSv Proximity Probes00 = Not required08=0.8in-52°C to +177°C (-62°F to70 7.0 meters (23.0 feet)12= 1.2in02= Miniature coaxial ClickLoc connector,standard cableAISI304 stainless steel (SST).
330908-12-08-70-02-053300 NSv Proximity Probes05 = Multiple Approvals08=0.8in-52°C to +177°C (-62°F to70 7.0 meters (23.0 feet)12= 1.2in02= Miniature coaxial ClickLoc connector,standard cableAISI304 stainless steel (SST).
330908-12-16-05-02-003300 NSv Proximity Probes00 Not required16=1.6 in-52°C to +177°C (-62°F to05 0.5 meter (20 in)12= 1.2 in02 = Miniature coaxial ClickLoc connector, standard cableAISI304 stainless steel (SST).

Values reproduced from manufacturer datasheets. "Not available" means the field is absent from the published source document. Always confirm critical parameters with the original documentation before specification.