Bently Nevada 3300 Extension Cables — 330730 Series Compared (Set 2)

14 models · Bently Nevada

AI-generated · verify with manufacturer

Bently Nevada 3300 Extension Cables — 330730 Series Compared (Set 2): side-by-side comparison of 14 sibling models from the same product line. Every value is extracted from the manufacturer documentation indexed in this wiki; a field shown as "Not available" is absent from the published source. Use the product links for full specifications, maintenance notes and sourcing guidance.

Specification comparison table

Bently Nevada 3300 Extension Cables — 330730 Series Compared (Set 2) — specifications compared across 14 models. Scroll horizontally to see all columns.
ModelProduct / Component TypeAgency Approval OptionConnectorConnector And Cable OptionExtension Cable CapacitanceExtension Cable MaterialLengthMaterial
330730-080-03-003300 XL 11 mm Extension Cable00 Not requiredprotectors are recommended for all03 Armored cable with connector69.9 pF/m (21.3 pF/ft) typical75 ? triaxial, fluoroethylene propylene (FEP) insulated.ofPolyphenylene sulfide (PPS).
330730-080-03-053300 XL 11 mm Extension Cable05 Multiple Approvalsprotectors are recommended for all03 Armored cable with connector69.9 pF/m (21.3 pF/ft) typical75 ? triaxial, fluoroethylene propylene (FEP) insulated.ofPolyphenylene sulfide (PPS).
330730-080-03-CN3300 XL 11 mm Extension CableCN Country Specificprotectors are recommended for all03 Armored cable with connector69.9 pF/m (21.3 pF/ft) typical75 ? triaxial, fluoroethylene propylene (FEP) insulated.ofPolyphenylene sulfide (PPS).
330730-080-10-00Not available00 = Not requiredprotectors are recommended for all10 = FluidLoc cable69.9 pF/m (21.3 pF/ft) typical75 ? triaxial, fluoroethylene propylene (FEP) insulated.ofPolyphenylene sulfide (PPS).
330730-080-10-053300 XL 11 mm Extension Cable05 Multiple Approvalsprotectors are recommended for all10 FluidLoc cable69.9 pF/m (21.3 pF/ft) typical75 ? triaxial, fluoroethylene propylene (FEP) insulated.ofPolyphenylene sulfide (PPS).
330730-080-10-CN3300 XL 11 mm Extension CableCN Country Specificprotectors are recommended for all10 FluidLoc cable69.9 pF/m (21.3 pF/ft) typical75 ? triaxial, fluoroethylene propylene (FEP) insulated.ofPolyphenylene sulfide (PPS).
330730-080-11-003300 XL 11 mm Extension Cable00 Not requiredprotectors are recommended for all11 Armored FluidLoc cable69.9 pF/m (21.3 pF/ft) typical75 ? triaxial, fluoroethylene propylene (FEP) insulated.ofPolyphenylene sulfide (PPS).
330730-080-11-053300 XL 11 mm Extension Cable05 Multiple Approvalsprotectors are recommended for all11 Armored FluidLoc cable69.9 pF/m (21.3 pF/ft) typical75 ? triaxial, fluoroethylene propylene (FEP) insulated.ofPolyphenylene sulfide (PPS).
330730-080-11-CN3300 XL 11 mm Extension CableCN Country Specificprotectors are recommended for all11 Armored FluidLoc cable69.9 pF/m (21.3 pF/ft) typical75 ? triaxial, fluoroethylene propylene (FEP) insulated.ofPolyphenylene sulfide (PPS).
330730-080-12-003300 XL 11 mm Extension Cable00 Not requiredprotectors are recommended for all12 FluidLoc cable with connector69.9 pF/m (21.3 pF/ft) typical75 ? triaxial, fluoroethylene propylene (FEP) insulated.ofPolyphenylene sulfide (PPS).
330730-080-12-053300 XL 11 mm Extension Cable05 Multiple Approvalsprotectors are recommended for all12 FluidLoc cable with connector69.9 pF/m (21.3 pF/ft) typical75 ? triaxial, fluoroethylene propylene (FEP) insulated.ofPolyphenylene sulfide (PPS).
330730-080-12-CN3300 XL 11 mm Extension CableCN Country Specificprotectors are recommended for all12 FluidLoc cable with connector69.9 pF/m (21.3 pF/ft) typical75 ? triaxial, fluoroethylene propylene (FEP) insulated.ofPolyphenylene sulfide (PPS).
330730-080-13-003300 XL 11 mm Extension Cable00 Not requiredprotector13 Armored FluidLoc cable with69.9 pF/m (21.3 pF/ft) typical75 ? triaxial, fluoroethylene propylene (FEP) insulated.ofPolyphenylene sulfide (PPS).
330730-080-13-053300 XL 11 mm Extension Cable05 Multiple Approvalsprotector13 Armored FluidLoc cable with69.9 pF/m (21.3 pF/ft) typical75 ? triaxial, fluoroethylene propylene (FEP) insulated.ofPolyphenylene sulfide (PPS).

Values reproduced from manufacturer datasheets. "Not available" means the field is absent from the published source document. Always confirm critical parameters with the original documentation before specification.