Overview

The IS200JPDSG1ACB is an automation component from GE. ### Functional Description.

Application & Technical Notes

As an automation component, the IS200JPDSG1ACB is intended for deployment in panel-based control cabinets and machine enclosures where the GE product portfolio equipment is installed. It performs a defined automation function within the control system and is selected to match the installed GE platform.

Specific electrical and mechanical ratings depend on the exact configuration and suffix of the part; the original datasheet should be consulted for the definitive specification.

Maintenance & Diagnostics

Inspect terminals and connectors for corrosion or looseness, and confirm the module seats correctly in its carrier. Always de-energise the circuit and follow lock-out/tag-out before handling; refer to the official instruction bulletin for service procedures.

Sourcing & Procurement

When sourcing the IS200JPDSG1ACB, distinguish three supply tiers: (1) genuine GE stock from an authorised distributor; (2) compatible equivalents or surplus/NOS (new-old-stock) from third parties; (3) alternative parts offering equivalent function. Genuine supply carries the full warranty and traceability; compatible or alternative items may be cheaper but should be validated for form, fit, firmware and certification before use in a live system. PLCXpert publishes this page as an independent reference and does not sell the part — verify every claim with the manufacturer or your distributor.

Confirm mechanical and electrical compatibility with your GE product portfolio installation and the intended function. Lead times and pricing vary by region and lifecycle status; obtain a current quote from an authorised channel rather than relying on stale listings.

Check live stock, lead time and request a quote for IS200JPDSG1ACB (opens in a new tab)

Frequently Asked Questions

What is the IS200JPDSG1ACB?

The IS200JPDSG1ACB is an automation component from GE. It belongs to GE's automation product portfolio.

What are the key technical ratings of the IS200JPDSG1ACB?

The definitive ratings depend on the exact configuration; consult the original datasheet or the source PDF linked on this page for the complete table.

How is the IS200JPDSG1ACB mounted or installed?

Installation follows the standard GE product portfolio mounting practice for this device class; refer to the installation manual for exact dimensions and torque.

Is the IS200JPDSG1ACB compatible with my controller?

It belongs to GE's automation product portfolio. Confirm the specific rack, firmware revision, slot rules and configuration with the controller documentation before purchase, as compatibility depends on the exact system build.

What should I check before buying the IS200JPDSG1ACB?

Verify the genuine part number and suffix, confirm it matches your platform and ratings, check the current lifecycle/availability status, and buy from an authorised distributor. PLCXpert provides this reference only and does not sell the component.

Specifications (source data)

Here is the information from the provided documents regarding the IS200JPDSG1ACB Power Distribution Board:

### Specifications

* **Part Number:** IS200JPDSG1ACB * **Manufacturer:** General Electric * **Series:** Mark VIe * **Product Type:** Power Distribution Board * **Country of Manufacture:** United States of America (USA) * **Operating Temperature:** -30 to +65°C (-22 to +149°F) * **Agency Approval:** Class 1 Division 2 explosive atmosphere * **Size:** 16.51 cm high x 17.8 cm wide * **Availability:** In Stock

### Functional Description

The IS200JPDSG1ACB is a GE-developed Power Distribution Board designed for the Mark VIe control system. Mounted on a sturdy sheet metal framework, it is specifically built to accommodate a PPDA I/O pack. The board incorporates three distinct 28 V DC power buses, each with its own dedicated bulk power supply input. While most output circuits lack fuses, three auxiliary circuits are exceptions. The design utilizes the current limit of connected power supplies to protect branch circuits. It communicates with the PPDA via ribbon cable to exchange system feedback, including DC bus voltage, power supply status contact feedback, and auxiliary circuit status.

### Installation

* **Mounting Options:** Can be mounted using either a vertical DIN-rail holder or a direct mounting metal holder. * **Wiring Guidance:** Refer to specific wiring diagrams for proper routing of power inputs and outputs. * **Diagnostic Connectors:** A 50-pin diagnostic connector is located on both the top and bottom of the board.

### Operation

The board serves as a critical component in the power distribution system by ensuring the uninterrupted operation of various subsystems. It receives 28 V DC power through three input connectors (JR, JS, and JT) and distributes it efficiently to boards, which in turn power the I/O packs. Proper functioning is essential to maintain system stability, and regular monitoring is recommended.

### I/O Characteristics

* **Power Input Connectors:** Three connectors (JR, JS, and JT) for 28 V DC power input. Each includes two connections for positive and three for negative power. Additionally, each source offers three power supply health inputs with two dry contact inputs each for diagnostic signals. * **DC Outputs for Rack Control:** Three DC outputs (JCR, JCS, and JCT) are provided to control rack CPCI power supplies. * **Outputs to JPDP Cards:** Six outputs (J1 to J6) are allocated via 3x2 Mate-N-Lok connectors, allowing for direct connection of up to six JPDL boards to supply I/O packs. * **Auxiliary Power Outputs:** Three outputs (JAR, JAS, and JAT) are dedicated to auxiliary power. Each features a positive temperature coefficient fuse for current limiting and a common-mode choke for noise suppression. * **Internal 28 V Bus Access:** Screw terminals (TB1 and TB2) provide access to the internal 28 V bus at the top and bottom of the board. These can handle a maximum continuous current of 35 A (75 A for the ground screw terminal) and can be used for jumpering boards together. * **Diagnostic Interface:** A DC-62 connector facilitates connectivity with the PPDA power diagnostic I/O pack, which monitors the JPDS and up to five additional power distribution boards via a 50-pin ribbon cable. * **P28 Power Output:** The P4 output is diode-ORed for the PPDA power diagnostic pack.

Reproduced from the manufacturer's published data.