IS200ERDDH1ABA
GE
Overview
The IS200ERDDH1ABA is a Dynamic Discharge Board from GE. It is part of GE's industrial automation product portfolio.
Application & Technical Notes
As a dynamic discharge board, the IS200ERDDH1ABA is intended for deployment in panel-based control cabinets and machine enclosures where the GE product portfolio equipment is installed. It performs a defined automation function within the control system and is selected to match the installed GE platform.
Specific electrical and mechanical ratings depend on the exact configuration and suffix of the part; the original datasheet should be consulted for the definitive specification.
Maintenance & Diagnostics
Inspect terminals and connectors for corrosion or looseness, and confirm the module seats correctly in its carrier. Always de-energise the circuit and follow lock-out/tag-out before handling; refer to the official instruction bulletin for service procedures.
Sourcing & Procurement
When sourcing the IS200ERDDH1ABA, distinguish three supply tiers: (1) genuine GE stock from an authorised distributor; (2) compatible equivalents or surplus/NOS (new-old-stock) from third parties; (3) alternative parts offering equivalent function. Genuine supply carries the full warranty and traceability; compatible or alternative items may be cheaper but should be validated for form, fit, firmware and certification before use in a live system. PLCXpert publishes this page as an independent reference and does not sell the part — verify every claim with the manufacturer or your distributor.
Confirm mechanical and electrical compatibility with your GE product portfolio installation and the intended function. Lead times and pricing vary by region and lifecycle status; obtain a current quote from an authorised channel rather than relying on stale listings.
Check live stock, lead time and request a quote for IS200ERDDH1ABA (opens in a new tab)
Frequently Asked Questions
What is the IS200ERDDH1ABA?
The IS200ERDDH1ABA is a dynamic discharge board from GE. It is described by the manufacturer as: Dynamic Discharge Board.
What are the key technical ratings of the IS200ERDDH1ABA?
The definitive ratings depend on the exact configuration; consult the original datasheet or the source PDF linked on this page for the complete table.
How is the IS200ERDDH1ABA mounted or installed?
Installation follows the standard GE product portfolio mounting practice for this device class; refer to the installation manual for exact dimensions and torque.
Is the IS200ERDDH1ABA compatible with my controller?
It belongs to GE's automation product portfolio. Confirm the specific rack, firmware revision, slot rules and configuration with the controller documentation before purchase, as compatibility depends on the exact system build.
What should I check before buying the IS200ERDDH1ABA?
Verify the genuine part number and suffix, confirm it matches your platform and ratings, check the current lifecycle/availability status, and buy from an authorised distributor. PLCXpert provides this reference only and does not sell the component.
Specifications (source data)
SPECIFICATIONS
Part No.: IS200ERDDH1ABA Manufacturer: General Electric Product Type: Dynamic Discharge Board Series: EX2100 Availability: In Stock Country of Origin: USA
IS200ERDDH1ABA is an IGBT Exciter Regulator Interface and the Dynamic Discharge board (ERDD) is used in the EX2100 Regulator Control, simplex, and redundant applications. One ERDD is installed in the IS200ERBP Exciter Regulator Backplane (ERBP) and interfaces with the IS200ERIOH A Exciter Regulator I/O board (ERIO) and the Exciter Regulator Static Converter board for simplex applications (ERSC). In redundant applications, one ERDD is installed in the ERBP (M1), while the other is installed in the Exciter Regulator Redundant Backplane (ERRB, M2/C) and interfaces with the ERIO, ERSC, and the Exciter Regulator Redundant Relay board (ERRR). The ERDD's main functions are as follows:
Field excitation gate drive control Dynamic discharge to manage dc-link voltage that is too high Monitor the dc-link voltage, output shunt current, output field voltage, bridge temperature, and IGBT gate drive status using bridge feedback (power supplies and desaturation conditions) In simplex applications, control of the de-excitation relay (K41) or in redundant applications, control of the charging relay (K3) With both P1 and P2 backplane connectors, the ERDD is a single-slot double-height (6U) form factor board. The ERDD board surface has seven connectors that link it to the boards it connects with. A board ID device is included in the ERDD and contains the following information:
Barcode Serial Number Board Type Hardware Revision ERDD Interface to Simplex IGBT Bridge Block Diagram
Fig 1: ERDD Interface to Simplex IGBT Bridge Block Diagram
BRIDGE HEATSINK TEMPERATURE SENSING
For temperature monitoring of the regulator bridge, one resistive temperature device (RTD) input is provided. This RTD input is scaled as a 0–140 °C input with a 0–10 V dc analog output. A block diagram of this function can be found below:
Bridge RTD Temperature Sensing Functional Block Diagram
Fig 2: Bridge RTD Temperature Sensing Functional Block Diagram
CONTROL POWER DISTRIBUTION
On ERDD, both control and dc-link voltages are present. The control power is isolated from any circuit or component connected to the IGBT bridge. The P1 and P2 backplane connectors supply non-isolated ERDD control circuits directly from the Exciter Power Supply Module (EPSM) input. The EPSM input also provides power for IGBT gating. The EPSM input and a redundant power source are used to power dynamic discharge (DD). The ERDD contains a redundant power source that is derived directly from the dc-link bus. The DD circuits monitor the dc-link voltage directly and apply control as needed (independent from the control processor). There are also six isolated power supplies derived from the secondary windings of two transformers on ERDD.
BRIDGE FEEDBACKS
Overcurrent Feedback: When a predefined full-scale shunt voltage level is achieved, the ERDD output current circuit detects overcurrent conditions. The feedback signal changes state when it reaches the overcurrent threshold level. The leg U IGBT gate driver and the output voltage VCO feedback circuit share transformer T1 with the output current feedback circuits (overcurrent and bridge output current VCO).
Bridge Output Current VCO Feedback: The voltage created across the bridge shunt is used to determine the output field current. At connection P6, the shunt output voltage is linked to the ERDD. After that, the 100 mV shunt signal is amplified and utilized to power a VCO (biased so that zero-field current produces a VCO frequency of 333 kHz). The shunt current feedback circuits have failed if frequencies less than the zero input signal frequency level is detected.
Bridge Output Voltage VCO Feedback: The output field voltage is monitored by an ERSC voltage attenuator. This attenuator generates a scaled feedback voltage in the -600 to +600 V dc output field voltage range. The ERDD is then connected to the attenuated signal, which is utilized to generate the output voltage feedback VCO (biased so that zero output voltage produces a VCO frequency of 1 MHz).
About the IS200ERDDH1ABA The IS200ERDDH1A model is part of the EX2100 series and is an Exciter Regulator Dynamics Discharge Board. The ERDD model has two operating modes, simplex and redundant. Each application mode is used differently as well as mounted differently.
When the IS200ERDDH1A is being used in simplex mode the model controls the K3 charging relay; when the board is being used in the redundant mode it will control the K41 de-excitation relay. The mounting places of the ERDD mode when operating in simplex and redundant mode are different, when in simplex mode the IS200ERDDH1A is mounted in the ERBP backplane and when in redundant mode two ERDD models must be used, one is mounted in the same location as the model in simplex mode and the other board will be mounted in the ERRB backplane.
Another function of the board is to provide feedback from the bridge to observe the output field and DC link voltages. When monitoring these the board also allows for observation of output shunt currents, IGBT gate drive statuses, and bridge temperature. The IS200ERDDH1A board is also typically used to control the excess DC link voltages through the dynamic discharge of the model.
Reproduced from the manufacturer's published data.