Skip to main content
PLCXpert Wiki

IS200EHPAG1DAB

GE

AI-generated · verify with manufacturerLast reviewed

Overview

The IS200EHPAG1DAB is an Exciter Gate Pulse Amplifier Board from GE. It is part of GE's industrial automation product portfolio.

Application & Technical Notes

As an exciter gate pulse amplifier board, the IS200EHPAG1DAB is intended for deployment in panel-based control cabinets and machine enclosures where the GE product portfolio equipment is installed. It performs a defined automation function within the control system and is selected to match the installed GE platform.

Key published characteristics include an operating temperature range of 0 to 70° C. These values should be confirmed against the current manufacturer datasheet before final selection, as options and suffixes vary by configuration.

Maintenance & Diagnostics

Respect the published operating temperature window (0 to 70° C); do not exceed it during commissioning or in enclosed panels without airflow. For storage and transit, keep the unit within -40 to 80° C. Inspect terminals and connectors for corrosion or looseness, and confirm the module seats correctly in its carrier. Always de-energise the circuit and follow lock-out/tag-out before handling; refer to the official instruction bulletin for service procedures.

Sourcing & Procurement

When sourcing the IS200EHPAG1DAB, distinguish three supply tiers: (1) genuine GE stock from an authorised distributor; (2) compatible equivalents or surplus/NOS (new-old-stock) from third parties; (3) alternative parts offering equivalent function. Genuine supply carries the full warranty and traceability; compatible or alternative items may be cheaper but should be validated for form, fit, firmware and certification before use in a live system. PLCXpert publishes this page as an independent reference and does not sell the part — verify every claim with the manufacturer or your distributor.

Confirm mechanical and electrical compatibility with your GE product portfolio installation and the intended function. Lead times and pricing vary by region and lifecycle status; obtain a current quote from an authorised channel rather than relying on stale listings.

Check live stock, lead time and request a quote for IS200EHPAG1DAB (opens in a new tab)

Frequently Asked Questions

What is the IS200EHPAG1DAB?

The IS200EHPAG1DAB is an exciter gate pulse amplifier board from GE. It is described by the manufacturer as: Exciter Gate Pulse Amplifier Board.

What are the key technical ratings of the IS200EHPAG1DAB?

Its published highlights include operating temperature 0 to 70° C. Full electrical, mechanical and environmental limits are listed in the manufacturer datasheet and should be confirmed for your exact suffix.

How is the IS200EHPAG1DAB mounted or installed?

Installation follows the standard GE product portfolio mounting practice for this device class; refer to the installation manual for exact dimensions and torque.

Is the IS200EHPAG1DAB compatible with my controller?

It belongs to GE's automation product portfolio. Confirm the specific rack, firmware revision, slot rules and configuration with the controller documentation before purchase, as compatibility depends on the exact system build.

What should I check before buying the IS200EHPAG1DAB?

Verify the genuine part number and suffix, confirm it matches your platform and ratings, check the current lifecycle/availability status, and buy from an authorised distributor. PLCXpert provides this reference only and does not sell the component.

Specifications (source data)

SPECIFICATIONS:

Part Number: IS200EHPAG1D Manufacturer: General Electric Series: EX2100 Microprocessor: Intel Celeron 650 MHz Memory: 128 MB SDRAM Operating system: QNX Product Type: Exciter Gate Pulse Amplifier Board Voltage Range: 14 to 32 V dc Maximum Lead Resistance: 15 Ω Storage temperature: -40 to 80° C Operating temperature: 0 to 70° C Technology: Surface mount Size: 16.2 cm high x 8.6 cm Repair: 3-7 Day Availability: In Stock Weight: 2 lbs Country of Origin: United States Manual: GEI-100532A

FUNCTIONAL DESCRIPTION:

IS200EHPAG1D is an Exciter Gate Pulse Amplifier Board manufactured and designed by General Electric as part of the EX2100 Series used in GE Excitation Control Systems. The IS200EHPA Gate Pulse Amplifier Board (EHPA) is a component of the 100 mm EX2100™ Excitation Control system. It processes gate commands from the ESEL to manage the firing of up to six Silicon Controlled Rectifiers (SCRs) on the Power Bridge. Additionally, it serves as an interface for monitoring current conduction, bridge airflow, and temperature. The EHPA’s functional model, highlighting its primary inputs and outputs, is illustrated in the accompanying diagram. Powered by a 125 V DC nominal source from the EPDM, the board features an onboard DC/DC converter to support SCR gating across the entire input voltage range. Status indicators, in the form of LEDs, provide visual feedback on various parameters, including EHPA power supply health, input gate commands from ESEL, SCR output signals, bridge current, line filter status, cooling fan operation, bridge temperature, alarms, and fault conditions.

GAT COMMAND INPUTS:

The EHPA receives six gate commands from the ESEL via a twisted-pair, multiconductor shielded cable. These commands are transmitted over differential pairs, where they are optically isolated, filtered, AC-coupled, and then directed to the Gate Pulse Amplifier (GPA). Each SCR has a dedicated GPA, ensuring independent operation. The EHPA also provides galvanic isolation between the gates of the individual SCRs.

SENSOR INPUTS:

The EHPA monitors conduction currents across all three phases of the bridge input. It functions as an interface between the Hall Effect sensors on the EXCS boards and the system controller. The EHPA supplies power to the EXCS and receives feedback signals from the EXCS, indicating the current flow status through each phase of the three-phase bridge input. These signals are received at connectors J9 and J10, where they are processed by the EHPA before transmitting the bridge status to the controller.

Bridge temperature is monitored via either an RTD (thermistor) sensor input or temperature switch input. For new exciters, only the RTD input is utilized, with jumpers on the EHPA disabling the temperature switch inputs. When retrofitting a bridge with an EX2100 control, the two temperature switch inputs are used to connect with the existing temperature switches on the bridge, and the RTD input is left disconnected to deactivate it. Both the RTD and temperature switch inputs are connected to the EHPA through J13. Airflow sensors (fan rotation) detect loss of fan cooling in the bridge. One fan can be connected to the EHPA through J12. The EHPA accepts either a pulsed or dry-contact, normally open sensor input from the fan. The mode of signal detection is configured through the berg jumper JP2.

Reproduced from the manufacturer's published data.