Skip to main content
PLCXpert Wiki

IC660TBD024

GE

AI-generated · verify with manufacturerLast reviewed

Overview

The IC660TBD024 is an automation component from GE. It is part of GE's industrial automation product portfolio.

Application & Technical Notes

As an automation component, the IC660TBD024 is intended for deployment in panel-based control cabinets and machine enclosures where the GE product portfolio equipment is installed. It performs a defined automation function within the control system and is selected to match the installed GE platform.

Key published characteristics include a 10 to 30 Volts DC rating, an operating temperature range of 0 to 60 degrees Celsius (32 to 140 degrees Fahrenheit). These values should be confirmed against the current manufacturer datasheet before final selection, as options and suffixes vary by configuration.

Maintenance & Diagnostics

Respect the published operating temperature window (0 to 60 degrees Celsius (32 to 140 degrees Fahrenheit)); do not exceed it during commissioning or in enclosed panels without airflow. Inspect terminals and connectors for corrosion or looseness, and confirm the module seats correctly in its carrier. Always de-energise the circuit and follow lock-out/tag-out before handling; refer to the official instruction bulletin for service procedures.

Sourcing & Procurement

When sourcing the IC660TBD024, distinguish three supply tiers: (1) genuine GE stock from an authorised distributor; (2) compatible equivalents or surplus/NOS (new-old-stock) from third parties; (3) alternative parts offering equivalent function. Genuine supply carries the full warranty and traceability; compatible or alternative items may be cheaper but should be validated for form, fit, firmware and certification before use in a live system. PLCXpert publishes this page as an independent reference and does not sell the part — verify every claim with the manufacturer or your distributor.

Confirm mechanical and electrical compatibility with your GE product portfolio installation and the intended function. Lead times and pricing vary by region and lifecycle status; obtain a current quote from an authorised channel rather than relying on stale listings.

Check live stock, lead time and request a quote for IC660TBD024 (opens in a new tab)

Frequently Asked Questions

What is the IC660TBD024?

The IC660TBD024 is an automation component from GE. It belongs to GE's automation product portfolio.

What are the key technical ratings of the IC660TBD024?

Its published highlights include 10 to 30 Volts DC, operating temperature 0 to 60 degrees Celsius (32 to 140 degrees Fahrenheit). Full electrical, mechanical and environmental limits are listed in the manufacturer datasheet and should be confirmed for your exact suffix.

How is the IC660TBD024 mounted or installed?

Installation follows the standard GE product portfolio mounting practice for this device class; refer to the installation manual for exact dimensions and torque.

Is the IC660TBD024 compatible with my controller?

It belongs to GE's automation product portfolio. Confirm the specific rack, firmware revision, slot rules and configuration with the controller documentation before purchase, as compatibility depends on the exact system build.

What should I check before buying the IC660TBD024?

Verify the genuine part number and suffix, confirm it matches your platform and ratings, check the current lifecycle/availability status, and buy from an authorised distributor. PLCXpert provides this reference only and does not sell the component.

Specifications

GENIUS Terminal Assembly for (TBD Only) TBD024 for IC660BBD024 IC660T IC660TB IC660TBD The IC660TBD024 Terminal Assembly is a screw-type Genius I/O terminal assembly module from GE Fanuc. It has a compact and rugged design. It is located between the IC660EBD024 Electronics Assembly and the IC660BBD024 I/O Block in the Genius I/O system. It is also known as the generic wiring base of the I/O module. This terminal assembly is the wiring interface between the I/O block and field devices. Its terminals are electrically connected together internally. The conductors and wires can be easily inserted into the terminal through the sloped entrance plane and the appropriately sized entrance holes. The IC660TBD024 Terminal Assembly makes the wiring and installation process of an I/O system clear and safe. The IC660TBD024 Terminal Assembly weighs 2 pounds. It has an EEPROM unit to store the configuration data including the device number, reference address, baud rate, and details of the BSM controller. It is not necessary to reconfigure the module when the electronics assembly is removed or replaced. It hosts all of the field wiring and power connections. The I/O block bus can be directly connected to this terminal assembly. The IC660TBD024 Terminal Assembly is compatible with the GE IC660BBD024 I/O Block and IC660EBD024 Electronics Assembly. The source type block’s outputs must be connected to the negative side of the power supply and the inputs can be connected to the positive side. It can assure the data integrity of the critical processes during replacement or renewal. This terminal assembly can be used to perform efficient field-wiring while ensuring safety and efficiency. The IC660TBD024 Genius I/O terminal assembly is an industrial automation component with a rated voltage of 12 or 24 Volts DC. The terminal assembly is made by GE Fanuc and it is used in different industries. The IC660TBD024 terminal assembly has a maximum ripple of 10% and 18 Watts of rated heat dissipation. Technical specifications for IC660TBD024 Brand GE Fanuc Series Genius I-O

Specifications

Operating Voltage10 to 30 Volts DC
Power SupplyDropout Time 4 milliseconds at 12 Volts / 20 milliseconds at 24 Volts
Dimensions(HxWxD) 224 x 90 x 112 millimeters (8.8 x 3.5 x 4.4 inches)
Weight1.8 kilograms (4 pounds)
Operating Temperature0 to 60 degrees Celsius (32 to 140 degrees Fahrenheit)
Storage Temperature-40 to 100 degrees Celsius (-40 to 212 degrees Fahrenheit) Description

Reproduced from the manufacturer's published data. Values marked "Not available" are absent from the source document.