Skip to main content
PLCXpert Wiki

IC660BBA105

GE

AI-generated · verify with manufacturerLast reviewed

Overview

The IC660BBA105 is an automation component from GE. The IC660BBA105 is a Current-source Analog 6 Output Block of GE Fanuc series 90-30 PLCs. It belongs to the Analog Output Modules group and can connect with eith.

Application & Technical Notes

As an automation component, the IC660BBA105 is intended for deployment in panel-based control cabinets and machine enclosures where the GE product portfolio equipment is installed. It performs a defined automation function within the control system and is selected to match the installed GE platform.

Key published characteristics include a 93-132 Volts AC/105-145 Volts DC rating. These values should be confirmed against the current manufacturer datasheet before final selection, as options and suffixes vary by configuration.

Maintenance & Diagnostics

Inspect terminals and connectors for corrosion or looseness, and confirm the module seats correctly in its carrier. Always de-energise the circuit and follow lock-out/tag-out before handling; refer to the official instruction bulletin for service procedures.

Sourcing & Procurement

When sourcing the IC660BBA105, distinguish three supply tiers: (1) genuine GE stock from an authorised distributor; (2) compatible equivalents or surplus/NOS (new-old-stock) from third parties; (3) alternative parts offering equivalent function. Genuine supply carries the full warranty and traceability; compatible or alternative items may be cheaper but should be validated for form, fit, firmware and certification before use in a live system. PLCXpert publishes this page as an independent reference and does not sell the part — verify every claim with the manufacturer or your distributor.

Confirm mechanical and electrical compatibility with your GE product portfolio installation and the intended function. Lead times and pricing vary by region and lifecycle status; obtain a current quote from an authorised channel rather than relying on stale listings.

Check live stock, lead time and request a quote for IC660BBA105 (opens in a new tab)

Frequently Asked Questions

What is the IC660BBA105?

The IC660BBA105 is an automation component from GE. It belongs to GE's automation product portfolio.

What are the key technical ratings of the IC660BBA105?

Its published highlights include 93-132 Volts AC/105-145 Volts DC. Full electrical, mechanical and environmental limits are listed in the manufacturer datasheet and should be confirmed for your exact suffix.

How is the IC660BBA105 mounted or installed?

Installation follows the standard GE product portfolio mounting practice for this device class; refer to the installation manual for exact dimensions and torque.

Is the IC660BBA105 compatible with my controller?

It belongs to GE's automation product portfolio. Confirm the specific rack, firmware revision, slot rules and configuration with the controller documentation before purchase, as compatibility depends on the exact system build.

What should I check before buying the IC660BBA105?

Verify the genuine part number and suffix, confirm it matches your platform and ratings, check the current lifecycle/availability status, and buy from an authorised distributor. PLCXpert provides this reference only and does not sell the component.

Specifications

The IC660BBA105 is a Current-source Analog 6 Output Block of GE Fanuc series 90-30 PLCs. It belongs to the Analog Output Modules group and can connect with either a 115 VAC or a 125 VDC power supply. A different version of the same equipment can be powered with 24/248VDC (IC660BBA025). It has six outputs whose output range is between 4 mA to 20 mA and provides the system with different types of diagnostics. Circuit power is isolated, and accuracy of input is as precise as 0.15% at 25C. Isolated power is provided to outputs by the block’s power source, and no additional power supply is needed for current loops of 4 to 20 mA. Outputs are electrically all the same. The outputs convert digital signals of 12 bits to analog signals for 0mA to 24mA. Values display on the handheld screen as integers, individually for every output. The IC660BBA105 Current-source Analog 6 Output Block has a dedicated bus switching module output that connects to specific BSM devices. The IC660BBA105 Current-source Analog 6 Output Block can be configured to hold the last output state, or a default state, and can receive output feedback and feedback time. The circuit transforms the signal to engineering values, and the block can work if there is CPU redundancy. This equipment also provides fault reporting that can be disabled if needed. Faults include output over-range and under-range signal detection and feedback recognition of less than 1.5 mA signals. All Genius bus controllers are compatible with IC660BBA105 Current-source Analog 6 Output Block. To configure the block, the user needs a handheld monitor of version 3.7 or above. The programming software is Logicmaster 6 ver. 4.02 or later. CPUs that are compatible with the block are rev. 105 or later for Series Six PLCs, rev.110 and above for Series Six Plus, and rev. 3.0 or later for series 5 PLCs. If a bus switching module is required, IC660BSM021 is the only compatible option. The IC660BBA105 Current-source Analog 6 Output Block has 32 terminals. Power source connects to terminals 6 and 7. Output cables connect to the self-powered inputs 11 to 32. Bus Switching Module connects to terminals 9-10. The IC660BBA105 is a Genius Block I/O. Previously manufactured by GE Fanuc, this module is now under Emerson Automation. It is a 115 VAC/ 125 VDC powered, stand-alone, current sourcing, analog output module that features Six (6) analog outputs that delivers 4-20 mA analog signals. This module has 6µA resolution. It supports Genius communication protocol, allowing the module to Technical specifications for IC660BBA105 Brand GE Fanuc Series Genius I/O

Specifications

OutputSignals 4-20 mA
Operating Voltage93-132 Volts AC/105-145 Volts DC

Reproduced from the manufacturer's published data. Values marked "Not available" are absent from the source document.