ABE7R16S210
Schneider Electric
Overview
The ABE7R16S210 is an Electromechanical output relay sub-base in the Modicon ABE7 range from Schneider Electric. It provides 16 channels and is built for signal interfacing within the Schneider Electric automation portfolio systems.
Application & Technical Notes
As an electromechanical output relay sub-base, the ABE7R16S210 is intended for deployment in panel-based control cabinets and machine enclosures where the Schneider Electric automation portfolio equipment is installed. It drives actuators, relays, valves and indicators from controller commands, acting as the actuation layer between logic and the machine.
Key published characteristics include 16 channels, an operating temperature range of -5…60 °C conforming to IEC 61131-2. These values should be confirmed against the current manufacturer datasheet before final selection, as options and suffixes vary by configuration.
Maintenance & Diagnostics
Respect the published operating temperature window (-5…60 °C conforming to IEC 61131-2); do not exceed it during commissioning or in enclosed panels without airflow. For storage and transit, keep the unit within -40…80 °C conforming to IEC 61131-2. Verify field wiring, shielding and grounding at installation; check terminal torque and confirm signal types match the configured range. Periodically inspect for loose terminations, induced noise and channel-level diagnostics reported by the controller. Always de-energise the circuit and follow lock-out/tag-out before handling; refer to the official instruction bulletin for service procedures.
Sourcing & Procurement
When sourcing the ABE7R16S210, distinguish three supply tiers: (1) genuine Schneider Electric stock from an authorised distributor; (2) compatible equivalents or surplus/NOS (new-old-stock) from third parties; (3) alternative parts offering equivalent function. Genuine supply carries the full warranty and traceability; compatible or alternative items may be cheaper but should be validated for form, fit, firmware and certification before use in a live system. PLCXpert publishes this page as an independent reference and does not sell the part — verify every claim with the manufacturer or your distributor.
Confirm the module matches your the Schneider Electric automation portfolio rack, the required channel count, signal type and voltage, and the firmware/configuration of the controller. Lead times and pricing vary by region and lifecycle status; obtain a current quote from an authorised channel rather than relying on stale listings.
Frequently Asked Questions
What is the ABE7R16S210?
The ABE7R16S210 is an electromechanical output relay sub-base in the Modicon ABE7 range from Schneider Electric. It is described by the manufacturer as: Electromechanical output relay sub-base.
What are the key technical ratings of the ABE7R16S210?
Its published highlights include 16 channels, operating temperature -5…60 °C conforming to IEC 61131-2. Full electrical, mechanical and environmental limits are listed in the manufacturer datasheet and should be confirmed for your exact suffix.
How is the ABE7R16S210 mounted or installed?
Installation follows the standard the Schneider Electric automation portfolio mounting practice for this device class; refer to the installation manual for exact dimensions and torque.
Is the ABE7R16S210 compatible with my controller?
It is part of the the Schneider Electric automation portfolio family. Confirm the specific rack, firmware revision, slot rules and configuration with the controller documentation before purchase, as compatibility depends on the exact system build.
What should I check before buying the ABE7R16S210?
Verify the genuine part number and suffix, confirm it matches your platform and ratings, check the current lifecycle/availability status, and buy from an authorised distributor. PLCXpert provides this reference only and does not sell the component.
Specifications
Schneider Electric ABE7R16S210
Main
| Note | Range of product Modicon ABE7 |
|---|---|
| Product or component | type Electromechanical output relay sub-base [Us] rated supply voltage 24 V DC for PLC end Number of channels 16 Number of terminal per channel 2 |
Complementary
| Note | Terminal block type Removable Polarity distribution Volt-free Fixing mode By clips (35 mm symmetrical DIN rail) By screws (solid plate with fixing kit) Maximum current per output common 10 A Current per channel 5 A for preactuator end Minimum switching current 10 mA at >= 5 V Drop-out voltage 2.4 V at 20 °C (PLC end) Switching frequency <= 0.5 Hz <= 10 Hz Threshold tripping voltage 19.7 V at 40 °C Drop-out current 1 mA at 20 °C Maximum power dissipation per channel in W 0.36 W (PLC end) Contacts type and composition 1 NO for preactuator end Maximum switching voltage 250 V AC 50/60 Hz conforming to IEC 60947-5-1 30 V DC conforming to IEC 60947-5-1 Electrical durability 500000 Cycles, maximum switching current: 600 mA at 24 V DC-13 10 ms (preactuator end) 500000 Cycles, maximum switching current: 1500 mA at 230 V AC-12 (preactuator end) 500000 Cycles, maximum switching current: 1500 mA at 24 V DC-12 (preactuator end) 500000 cycles, maximum switching current: 900 mA at 230 V AC-15 (preactuator end) Electrical reliability 1e-008 Operating time <= 10 ms coil energisation and NO closing <= 5 ms coil de-energisation and NO opening Contact bounce time <= 5 ms 1 NO Operating rate in Hz 10 Hz no load 0.5 Hz at Ie Mechanical durability 20000000 cycles [Uimp] rated impulse withstand voltage 2.5 kV conforming to IEC 60947-1 [Ui] rated insulation voltage 2000 V Installation category II conforming to IEC 60664-1 Tightening torque 0.6 N.m with flat Ø 3.5 mm screwdriver Width 206 mm Net weight 0.405 kg |
|---|
Environment
| Note | Max immunity to microbreaks 5 ms Dielectric strength 2000 V conforming to IEC 60947-1 Product certifications GL CSA DNV UL EAC IP degree of protection IP2X conforming to IEC 60529 Protective treatment TC Resistance to incandescent wire 750 °C, extinction time <30 s conforming to IEC 60695-2-11 Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27 Resistance to radiated fields 10 V/m (26000000…1000000000 Hz) conforming to IEC 61000-4-3 level 3 Resistance to fast transients 2 kV level 3 conforming to IEC 61000-4-4 Ambient air temperature for operation -5…60 °C conforming to IEC 61131-2 Ambient air temperature for storage -40…80 °C conforming to IEC 61131-2 |
|---|---|
| Pollution degree 2 conforming to IEC 60664-1 | N/A |
Packing Units
| Unit Type of Package 1 PCE | Number of Units in Package 1 1 Package 1 Height 7.000 cm Package 1 Width 8.200 cm Package 1 Length 21.100 cm Package 1 Weight 581.000 g |
|---|
Reproduced from the manufacturer's published data. Values marked "Not available" are absent from the source document.